R-134a PT Chart

Look up R-134a saturation pressure or temperature, or scan the full chart below. R-134a is a single-component refrigerant, so one pressure column covers both superheat and subcooling.

Look up
Gauge pressure unit

For a vacuum, pick inHg and enter the gauge reading.

Answer in

Saturation temperature

–

Fill in the boxes above to see the answer.

R-134a pressure-temperature chart

Gauge pressure at sea level. R-134a is a single-component refrigerant, so liquid and vapor saturate at the same pressure. Values marked inHg are vacuum, in inches of mercury.

R-134a saturation pressure by temperature, °F and psig
°Fpsig
-4014.8 inHg
-3914.4 inHg
-3813.9 inHg
-3713.4 inHg
-3613.0 inHg
-3512.5 inHg
-3412.0 inHg
-3311.4 inHg
-3210.9 inHg
-3110.4 inHg
-309.8 inHg
-299.3 inHg
-288.7 inHg
-278.1 inHg
-267.5 inHg
-256.9 inHg
-246.3 inHg
-235.7 inHg
-225.0 inHg
-214.3 inHg
-203.7 inHg
-193.0 inHg
-182.3 inHg
-171.5 inHg
-160.8 inHg
-150.1 inHg
-140.4
-130.7
-121.1
-111.5
-101.9
-92.4
-82.8
-73.2
-63.6
-54.1
-44.6
-35.0
-25.5
-16.0
06.5
17.0
27.5
38.0
48.5
59.1
69.6
710.2
810.8
911.3
1011.9
1112.5
1213.1
1313.8
1414.4
1515.0
1615.7
1716.4
1817.0
1917.7
2018.4
2119.1
2219.9
2320.6
2421.3
2522.1
2622.9
2723.7
2824.5
2925.3
3026.1
3126.9
3227.8
3328.6
3429.5
3530.4
3631.3
3732.2
3833.1
3934.1
4035.0
4136.0
4237.0
4338.0
4439.0
4540.1
4641.1
4742.2
4843.2
4944.3
5045.4
5146.6
5247.7
5348.9
5450.0
5551.2
5652.4
5753.6
5854.9
5956.1
6057.4
6158.7
6260.0
6361.3
6462.7
6564.0
6665.4
6766.8
6868.2
6969.7
7071.1
7172.6
7274.1
7375.6
7477.1
7578.7
7680.2
7781.8
7883.4
7985.0
8086.7
8188.4
8290.0
8391.8
8493.5
8595.2
8697.0
8798.8
88100.6
89102.5
90104.3
91106.2
92108.1
93110.0
94112.0
95113.9
96115.9
97118.0
98120.0
99122.1
100124.2
101126.3
102128.4
103130.6
104132.7
105135.0
106137.2
107139.5
108141.7
109144.0
110146.4
111148.7
112151.1
113153.5
114156.0
115158.4
116160.9
117163.4
118166.0
119168.6
120171.2
121173.8
122176.5
123179.1
124181.8
125184.6
126187.4
127190.1
128193.0
129195.8
130198.7
131201.6
132204.6
133207.5
134210.6
135213.6
136216.7
137219.7
138222.9
139226.0
140229.2
141232.4
142235.7
143239.0
144242.3
145245.7
146249.0
147252.5
148255.9
149259.4
150262.9
R-134a saturation pressure by temperature, °C and kPa
°CkPa
-40-50
-39-47
-38-45
-37-42
-36-38
-35-35
-34-32
-33-28
-32-25
-31-21
-30-17
-29-13
-28-9
-27-4
-260
-255
-2410
-2315
-2220
-2126
-2031
-1937
-1843
-1750
-1656
-1563
-1469
-1377
-1284
-1191
-1099
-9107
-8116
-7124
-6133
-5142
-4151
-3161
-2171
-1181
0191
1202
2213
3225
4236
5248
6261
7273
8286
9300
10313
11327
12342
13356
14372
15387
16403
17419
18436
19453
20470
21488
22507
23525
24544
25564
26584
27605
28626
29647
30669
31691
32714
33737
34761
35786
36811
37836
38862
39888
40915
41943
42971
431,000
441,029
451,059
461,089
471,120
481,152
491,184
501,217
511,250
521,284
531,319
541,354
551,390
561,427
571,464
581,502
591,541
601,580
611,621
621,661
631,703
641,745
651,788

You're free to reuse this chart's numbers under CC BY 4.0. Just credit Pocket HVAC and link back to this page.

What is an R-134a PT chart?

An R-134a PT chart lists the pressure R-134a boils and condenses at for each temperature. At 40°F that's just 35.0 psig, and below about -15°F it drops into a vacuum. It's a single-component refrigerant sold as Freon 134a, Forane 134a, Genetron 134a and Klea 134a.

Anywhere liquid and vapor are together in a system, like inside the evaporator and condenser coils, the pressure and temperature are locked together, so one tells you the other. On the job, the chart turns gauge readings into saturation temperatures: the suction pressure gives the temperature the evaporator is boiling at, and the liquid line pressure gives the temperature the condenser is condensing at. Compare those with your line temperatures and you have superheat and subcooling.

R-134a is a single-component refrigerant (safety class A1) that runs at much lower pressures than R-410A. In HVAC you'll mostly find it in chillers, and it was the standard refrigerant in car air conditioning for years.

How it's calculated

Absolute pressure = gauge pressure + 14.696 psi (101.325 kPa, one standard atmosphere)
Saturation data: R-134a: CoolProp 8.0.0, R134a
Between table points (every 0.5 °C): ln(pressure) is interpolated linearly in 1 ÷ absolute temperature
Printed chart rows are solved by CoolProp at each exact temperature

Sources

If a number doesn't match your chart, email me what you entered and what you expected, and I'll check it against the source. You can also read how the numbers are checked.

Checked by Paul Williams · Updated

Questions

What is the R-134a pressure at 40°F?

R-134a's saturation pressure at 40°F is 35.0 psig. At 100°F it's 124.2 psig.

Why does the chart show inHg at low temperatures?

Below about -15°F, R-134a's saturation pressure is under atmospheric, so a gauge reads a vacuum. The chart shows those rows in inches of mercury, like a compound gauge.

How accurate is this chart?

It comes from the NIST equation of state for R-134a through CoolProp, and matches NIST's own tables to within 0.01 psi.